§ 45.1-161.126. Surface storage of explosives

VA Code § 45.1-161.126 (2019) (N/A)
Copy with citation
Copy as parenthetical citation

A. Separate surface magazines shall be provided for the storage of explosives and detonators.

B. Surface magazines for storing and distributing explosives in amounts exceeding 150 pounds shall be:

1. Reasonably bulletproof and constructed of incombustible material or covered with fire-resistive material. The roofs of magazines so located that it is impossible to fire bullets directly through the roof from the ground need not be bulletproof, but where it is possible to fire bullets directly through them, roofs shall be made bullet-resistant by material construction, or by a ceiling that forms a tray containing not less than a four-inch thickness of sand, or by other methods;

2. Provided with doors constructed of three-eighth inch steel plate lined with a two-inch thickness of wood, or the equivalent;

3. Provided with dry floors made of wood or other nonsparking material and have no metal exposed inside the magazine;

4. Provided with suitable warning signs so located that a bullet passing directly through the face of a sign will not strike the magazine;

5. Provided with properly screened ventilators;

6. Equipped with no openings except for entrance and ventilation;

7. Kept locked securely when unattended; and

8. Electrically bonded and grounded if constructed of metal.

C. Surface magazines for storing detonators need not be bulletproof, but they shall conform to the other provisions of subsection B regarding the storage of explosives.

D. Explosives in amounts of 150 pounds or less or 5,000 detonators or less shall be stored in accordance with preceding standards or in separate locked box-type magazines. Box-type magazines may also be used as distributing magazines when quantities do not exceed those mentioned. Box-type magazines shall be constructed strongly of two-inch hardwood or the equivalent. Metal magazines shall be lined with nonsparking material. No magazine shall be placed in a building containing oil, grease, gasoline, wastepaper or other highly flammable material; nor shall a magazine be placed within 20 feet of a stove, furnace, open fire or flame.

E. Magazines shall be located not less than 300 feet from any mine opening. However, in the event that a magazine cannot be practicably located at such a distance, a magazine may be located less than 300 feet from any mine opening, if it is sufficiently barricaded and approved by the Chief. Unless approved by the Chief, magazines shall not be located closer to occupied buildings, public roads, or passenger railways than allowed in the "American Table of Distances for Storage of Explosive Materials."

F. The supply kept in distribution magazines shall be limited to approximately a 48-hour supply, and such supplies of explosives and detonators may be distributed from the same magazine, if separated by at least a four-inch substantially fastened hardwood partition or equivalent barrier.

G. The area surrounding magazines for not less than 25 feet in all directions shall be kept free of rubbish, dry grass or other materials of a combustible nature.

H. If the explosives magazine is illuminated electrically, vapor-proof lamps shall be installed and wired so as to present minimum fire and contact hazards.

I. Only nonmetallic tools shall be used for opening wooden explosives containers. Extraneous materials shall not be stored with explosives or detonators in an explosives magazine.

Code 1950, § 45-53.2; 1954, c. 191; 1966, c. 594, § 45.1-44; 1978, c. 729; 1994, c. 28; 2005, c. 3.